Company Logo
ENTERPRISE IT INFRASTRUCTURE & CYBERSECURITY
Skip to content
Data Centre Solutions | Microlines Infotech Enterprise IT
ac_unit 24/7 Datacenter Thermal & Power Infrastructure Emergency Hotline
verified_user Green Datacenter PUE 1.15 Target & N+1 / 2N Modular Power SLA
DC Facility Team: +91 98765 43210 arrow_forward
HomeSolutionsData Centre Solutions

Data Centre Solutions

Turnkey physical datacenter facility engineering: Precision Air Conditioning (PAC) with hot/cold aisle containment, modular 3-phase online UPS power distribution with switched iPDUs, and 42U/48U high-perforation airflow server racks.

mode_fan PAC Precision In-Row Cooling
power Modular 3-Phase Online UPS & iPDUs
shelves 42U/48U 80%+ Airflow Server Racks
1.15 PUE Target Energy Efficiency Ratio
N+1 / 2N Modular Power Redundancy
± 0.5°C Precision Thermal Control
80%+ High Mesh Airflow Perforation

Our Turnkey Datacenter Engineering Lifecycle

Comprehensive physical infrastructure design, installation, and commissioning

01
thermostat

CFD Thermal & Power Sizing

Computational Fluid Dynamics (CFD) airflow simulation, electrical kW load calculation, and raised-floor planning.

02
construction

Containment & Busway Build

Erecting hot/cold aisle containment, installing modular 3-phase UPS units, overhead busway power, and precision PAC units.

03
verified

Testing & DCIM Monitoring

Integrated thermal load testing, Fluke fiber certification, and activating 24/7 Datacenter Infrastructure Management (DCIM).

Precision Air Conditioning PAC In Row Cooling PRECISION PAC & CONTAINMENT
SUB-SERVICE 5.1

Cooling Infrastructure

Precision Air Conditioning (PAC) units, In-Row cooling modules, and Hot/Cold Aisle Containment systems designed to eliminate thermal hotspots and maintain exact temperature (±0.5°C) and humidity (±2% RH) tolerances for high-density server racks.

Cooling Technologies In-Row Chilled Water (CW), Direct Expansion (DX), Perimeter PAC Units
Aisle Containment Hot Aisle Containment (HAC) & Cold Aisle Containment (CAC) Doors
Environmental Control Precision Temperature (±0.5°C) & Relative Humidity (±2% RH)
Energy Efficiency Variable EC Fans & Inverter Compressors for PUE Optimization
Read Full Specs
SUB-SERVICE 5.2

Power & Distribution Infrastructure

Modular 3-Phase Online Double-Conversion UPS systems (N+1 / 2N redundant configuration), intelligent Switched iPDUs with per-outlet energy metering, and overhead track busway power distribution for zero-downtime server operations.

UPS Architecture Modular 3-Phase Double-Conversion Online UPS (scalable up to 1MW)
Redundancy Model N+1, N+2 & 2N Dual-Bus Redundant Power Paths
Smart iPDUs Rack Switched iPDUs with Per-Outlet Power Metering & Remote Reboot
Battery Systems Long-Life Lithium-Ion (LiFePO4) & Modular VRLA Battery Racks
Read Full Specs
Modular 3 Phase UPS Power System MODULAR 3-PHASE UPS
42U 48U Server Racks High Airflow Perforation 42U / 48U HIGH-AIRFLOW RACKS
SUB-SERVICE 5.3

Rack & Cabinet Infrastructure

Heavy-duty 42U and 48U server racks with 80%+ hexagonal mesh airflow perforation, integrated vertical cable management fingers, tool-less iPDU mounting channels, and combination biometric electronic door locks.

Rack Formats 42U, 48U & 52U Industry-Standard 19-Inch Server Cabinets
Airflow Perforation 80%+ Hexagonal Honeycomb Perforated Mesh Front/Rear Doors
Weight Capacity Heavy-Duty Steel Frame supporting 1,500 kg Dynamic Load
Physical Security Biometric RFID Electronic Handle Locks & Environmental Sensors
Read Full Specs

Speak with a certified Microlines datacenter engineer for a customized physical facility & power proposal.

Turnkey Data Centre Infrastructure Hardware

Precision Air Conditioning (PAC), Modular 3-Phase Online UPS, and 42U/48U High-Airflow Racks.

In-Row PAC Cooling Unit

In-Row Precision AC (PAC) Cooling

EC Fan & Hot-Aisle Containment

30kW – 60kW In-Row Cooling, variable speed EC fans, R410a eco-refrigerant, dual power inputs, PUE < 1.15 efficiency.

Modular 3-Phase Online UPS

Modular 3-Phase Online UPS System

100kVA – 500kVA Scalable Power

N+1 redundancy, 96.5% double-conversion efficiency, hot-swappable power modules, Lithium-Ion battery bank support.

42U Server Rack Cabinet

42U / 48U Server Rack Cabinet

80% High-Perforation Airflow

1500kg static load rating, dual vertical cable managers, smart iPDU mounting, combination lock doors.

Switched iPDU Rack Unit

Switched Rack iPDU Power Distribution

Per-Outlet Monitoring & Switching

32A 3-Phase Feed, 24x C13 + 6x C19 outlets, billing-grade kWh metering, environmental temp/humidity sensor ports.

Frequently Asked Questions

Hot/Cold aisle containment design, PUE optimization, and N+1 power backup design.

1. How does Hot-Aisle Containment (HAC) lower Data Center PUE below 1.2?
HAC physically isolates hot exhaust air (40°C+) from cold supply air (24°C), preventing air mixing. This allows PAC units to operate at higher return temperatures, reducing compressor work and driving total PUE down to 1.15.
2. What is the benefit of Lithium-Ion over Lead-Acid (VRLA) UPS batteries?
Lithium-Ion batteries offer 3x longer lifespan (10-15 years), 60% less footprint weight, 3x faster recharge times, and higher temperature tolerance, significantly lowering total cost of ownership (TCO).